							| Analogue Input - 2-wire transmitters, 4-20mA conventional and 'smart' |  
							| Device | No. of channels
 | Output to hazardous area
 | Important features |  
							| DIN-rail mounting devices |  
							| MTL5541 | 1 | 16.5V min. @ 20mA
 | Compatible with most smart transmitters |  
							| MTL5541A | 1 | 8.6V diode | Separately powered smart transmitters |  
							| MTL5541AS | 1 | 8.6V diode | 4 wire smart transmitters, current sink output |  
							| MTL5541S | 1 | 16.5V min. @20mA
 | Compatible with most smart transmitters, current sink output |  
							| MTL5544 | 2 | 16.5V min @ 20mA
 | Compatible with most smart transmitters |  
							| MTL5544A | 2 | 8.6V diode | Separately powered smart transmitters |  
							| MTL5544AS | 2 | 8.6V diode | 4 wire smart transmitters, current sink output |  
							| MTL5544D | 1 | 16.5V min @ 20mA
 | Compatible with most smart transmitters, repeat output |  
							| MTL5544S | 2 | 16.5V min @ 20mA
 | Compatible with most smart transmitters, current sink output |  
							| Backplane mounting devices |  
							| MTL4541 | 1 | 16.5V min @ 20mA
 | Compatible with most smart transmitters |  
							| MTL4541A | 1 | 8.6V diode | Separately powered smart tranmitters |  
							| MTL4541AS | 1 | 8.6V diode | 4 wire smart transmitter, current sink output |  
							| MTL4541B | 1 | 16.5V min @ 20mA
 | As MTL4541 but adapted for MTL4041B substitution on legacy backplanes |  
							| MTL4541P | 1 | 17.6V min @ 20mA
 | As MTL4541B but with a higher power output, MTL4041P substitution on legacy backplanes |  
							| MTL4541S | 1 | 16.5V min @ 20mA
 | Compatible with most smart transmitters, current sink output |  
							| MTL4544 | 2 | 16.5V min @ 20mA
 | Compatible with most smart transmitters |  
							| MTL4544A | 2 | 8.6V diode | Separately powered smart transmitters |  
							| MTL4544AS | 2 | 8.6V diode | 4 wire smart transmitters, current sink output |  
							| MTL4544B | 1 | 16.5V min @ 20mA
 | As MTL4544 but adapted for MTL4044B substitution on legacy backplanes |  
							| MTL4544D | 1 | 16.5V min @ 20mA
 | Compatible with most smart transmitters, repeat output |  
							| ^ Top |  | 
		
			| 
					
						
							| Analogue Input - vibration transducer |  
							| Device | No. of channels
 | Signal monitored | Main features |  
							| DIN-rail mounting devices |  
							|  |  
							| MTL5531 | 1 | Vibration transducer
 | Compatible with vibration and accelerometer transducers |  
							| MTL5533 | 2 | Vibration transducer
 | Compatible with vibration and accelerometer transducers |  
							| Backplane mounting devices |  
							| MTL4531 | 1 | Vibration transducer
 | Compatible with vibration and accelerometer transducers |  
							| ^ Top |  | 
		
			| 
					
						
							| Analogue Input - thermocouple and mV sources |  
							| Device | No. of channels
 | Output to safe area
 | Main features |  
							| DIN-rail mounting devices |  
							| MTL5573 | 1 | 4/20mA | Configurable, built-in CJC, early burnout detection facility |  
							| MTL5575 | 1 | 4/20mA | Configurable, built-in CJC, early burnout detection facility, alarm output |  
							| MTL5576-THC | 2 | 4/20mA | Configurable, built-in CJC, also config as 1in 2 out |  
							| MTL5581 | 1 | 0 to ±50mV | Selectable upscale or downscale |  
							| Backplane mounting devices |  
							| MTL4573 | 1 | 4/20mA | Configurable, built-in CJC, early burnout detection facility |  
							| MTL4575 | 1 | 4/20mA | Configurable, built-in CJC, early burnout detection facility, alarm output |  
							| MTL4576-THC | 2 | 4/20mA | Configurable, built-in CJC, also config as 1in 2 out |  
							| MTL4581 | 1 | 0 to ±50mV | Selectable upscale or downscale |  
							| ^ Top |  | 
		
			| 
					
						
							| Analogue Input - 2, 3 and 4-wire RTDs |  
							| Device | No. of channels
 | Output to safe area
 | Main features |  
							| DIN-rail mounting devices |  
							| MTL5573 | 1 | 4/20mA | Configurable, many sensor types and ranges |  
							| MTL5575 | 1 | 4/20mA | Configurable, many sensor types and ranges, alarm output |  
							| MTL5576-RTD | 2 | 4/20mA | Configurable, also config as 1in 2 out |  
							| MTL5582B | 1 | 10 to 400 ohm | Independent selection of 2, 3 or 4-wire RTDs on safe and hazardous area sides |  
							| Backplane mounting devices |  
							| MTL4573 | 1 | 4/20mA | Configurable, many sensor types and ranges |  
							| MTL4575 | 1 | 4/20mA | Configurable, many sensor types and ranges, alarm output |  
							| MTL4576-RTD | 2 | 4/20mA | Configurable, also config as 1in 2 out |  
							| ^ Top |  | 
		
			|  | 
		
			| 
					
						
							| Analogue Output - controller outputs, I/P converters |  
							| Device | No. of channels
 | Output to hazardous area
 | Important features |  
							| DIN-rail mounting devices |  
							| MTL5546 | 1 | 1mA Vmax = 16V | Suitable for HART valve positioners, SC & OC LFD |  
							| MTL5546Y | 1 | 1mA Vmax = 16V | Suitable for HART valve positioners, OC LFD |  
							| MTL5549 | 2 | 1mA Vmax = 16V | Suitable for HART valve positioners, SC & OC LFD |  
							| MTL5549Y | 2 | 1mA Vmax = 16V | Suitable for HART valve positioners, OC LFD |  
							| Backplane mounting devices |  
							| MTL4546 | 1 | 1mA Vmax = 16V | Suitable for HART valve positioners, SC & OC LFD |  
							| MTL4546Y | 1 | 1mA Vmax = 16V | Suitable for HART valve positioners, OC LFD |  
							| MTL4549 | 2 | 1mA Vmax = 16V | Suitable for HART valve positioners, SC & OC LFD |  
							| MTL4549Y | 2 | 1mA Vmax = 16V | Suitable for HART valve positioners, OC LFD |  
							| ^ Top |  | 
		
			| 
					
						
							| Digital Input - switches / proximity detectors |  
							| Device | No. of channels
 | Output to safe area
 | Important features |  
							| DIN-rail mounting devices |  
							| MTL5510 | 4 | 4 x solid state | Can switch +ve or –ve polarity signals |  
							| MTL5510B | 4 | 4 x solid state | Mult-function selectable |  
							| MTL5511 | 1 | 1 x SPDT | Switch/proximity detector repeater |  
							| MTL5513 | 2 | 2 x solid state | dc to 500Hz frequency response |  
							| MTL5514 | 1 | 1 x SPDT 1 x SPDT
 | Switch/proximity detector repeater Independent LFD output
 |  
							| MTL5514D | 1 | 2 x SPDT | Dual output switch/proximity detector repeater |  
							| MTL5516C | 2 | 2 x SPDT | Switch/proximity detector repeater |  
							| MTL5517 | 2 | 2 x SPDT 1 x SPDT
 | Switch/proximity detector repeater Independent LFD output
 |  
							| Backplane mounting devices |  
							| MTL4504 | 1 | 1 x SPDT 1 x SPDT
 | Switch/proximity detector repeater Independent LFD output, de-energise to alarm
 |  
							| MTL4510 | 4 | 4 x solid state | Can switch +ve or –ve polarity signals |  
							| MTL4510B | 4 | 4 x solid state | Mult-function selectable switches +ve, -ve or ac signals
 |  
							| MTL4511 | 1 | 1 x SPDT | Switch/proximity detector repeater |  
							| MTL4513 | 2 | 2 x solid state | dc to 500Hz frequency response |  
							| MTL4514 | 1 | 1 x SPDT 1 x SPDT
 | Switch/proximity detector repeater Independent LFD output, energise to alarm
 |  
							| MTL4514D | 1 | 2 x SPDT | Dual output switch/proximity detector repeater |  
							| MTL4516 | 2 | 2 x SPST | Switch/proximity detector repeater |  
							| MTL4516C | 2 | 2 x SPDT | Switch/proximity detector repeater |  
							| MTL4517 | 2 | 2 x SPST 1 x SPDT
 | Switch/proximity detector repeater Independent LFD output
 |  
							| ^ Top |  | 
		
			| 
					
						
							| Digital Input - switch/proximity detectors, SIL3 |  
							| Device | No. of channels
 | Signals monitored | Important features |  
							| DIN-rail mounting devices |  
							| MTL5501-SR | 1 | 24V logic | Safety related, SIL3 certified |  
							| Backplane mounting devices |  
							| MTL4501-SR | 1 | 24V logic | Safety related, SIL3 certified |  
							| ^ Top |  | 
		
			| 
					
						
							| Digital Output - alarms, LEDs, solenoid valves, etc |  
							| Device | No. of channels
 | Output to hazardous area
 | Important features |  
							| DIN-rail mounting devices |  
							| MTL5521 | 1 | 12.8V Imax = 48mA | IIC gas groups, loop powered |  
							| MTL5522 | 1 | 9.9V Imax = 70mA | IIB gas groups, loop powered |  
							| MTL5523 | 1 | 12.8V Imax = 48mA | Switch controlled input, Independent LFD output |  
							| MTL5523V | 1 | 12.8V Imax = 48mA | Voltage controlled input, Independent LFD output |  
							| MTL5524 | 1 | 12.8V Imax = 48mA | Safety override feature, separately powered |  
							| MTL5525 | 1 | 7V Imax = 48mA | Low power output, loop powered |  
							| Backplane mounting devices |  
							| MTL4521 | 1 | 12.8V Imax = 48mA | Loop powered |  
							| MTL4521L | 1 | 10.3V Imax = 48mA | Loop powered |  
							| MTL4523 MTL4523R
 | 1 | 12.8V Imax = 48mA | Switch controlled input, Independent LFD output |  
							| MTL4523L | 1 | 12.8V Imax = 48mA | Loop powered, independent LFD output |  
							| MTL4523V | 1 | 12.8V Imax = 48mA | Voltage controlled input, Independent LFD output |  
							| MTL4524 & MTL4524S
 | 1 | 12.8V Imax = 48mA | Safety override feature, separately powered |  
							| MTL4525 | 1 | 7V Imax = 48mA | Safety override, low power output |  
							| ^ Top |  | 
		
			| 
					
						
							| Digital Output - switch output to hazardous area |  
							| Device | No. of channels
 | Signals monitored | Important features |  
							| DIN rail mounting devices |  
							| MTL5526 | 1 or 2 | 2 x DPDT | Safe-area switch input or loop powered. 2ch or 1ch with 2 outputs
 |  
							| Backplane mounting devices |  
							| MTL4526 | 1 or 2 | 2 x DPDT | Safe-area switch input or loop powered. 2ch or 1ch with 2 outputs
 |  
							| ^ Top |  | 
		
			| 
					
						
							| Pulse Input - turbine / flowmeters |  
							| Device | No. of channels
 | Input from hazardous area
 | Important features |  
							| DIN-rail mounting devices |  
							| MTL5532 | 1 | Switch, proximity detector, current pulse, voltage pulse | Voltage and current inputs from 2 or 3-wire transmitters configurable 4-20mA analogue output
 |  
							| MTL5541 | 1 | 2-wire pulse | e.g. 2-wire turbine and vortex flowmeters |  
							| Backplane mounting devices |  
							| MTL4532 | 1 | 1mA Vmax = 16V | Voltage and current inputs from 2 or 3-wire transmitters configurable 4-20mA analogue output
 |  
							| MTL4541 | 1 | 2-wire pulse | e.g. 2-wire turbine and vortex flowmeters |  
							| ^ Top |  | 
		
			| 
					
						
							| Fire / Smoke detectors |  
							| Device | No. of channels
 | Output to hazardous area
 | Important features |  
							| DIN-rail mounting devices |  
							| MTL5561 | 2 | Loop powered | 0–40mA, fire and smoke detectors |  
							| Backplane mounting devices |  
							| MTL4561 | 2 | Loop powered | 0–40mA, fire and smoke detector |  
							| ^ Top |  | 
		
			| 
					
						
							| Signal transfer - safe area to safe area - via hazardous area |  
							| Device pair
 | No. of channels
 | Signal transferred | Important features |  
							| DIN-rail mounting devices |  
							| MTL5546Y & MTL5541A
 | 1 | 4/20mA smart | Driver Receiver
 |  
							| MTL5526 & MTL5516C
 | 2 | Status signals | Driver, relay output Receiver, digital output
 |  
							| MTL5051 | 1 | RS232 or RS422 | Either can be used as receiver or driver |  
							| Backplane mounting devices |  
							| MTL4546Y & MTL4541A
 | 1 | 4/20mA smart | Driver Receiver
 |  
							| MTL4526 & MTL4516
 | 2 | Status signals | Driver, relay output Receiver, digital output
 |  
							| ^ Top |  | 
		
			| 
					
						
							| Trip amplifiers |  
							| Device | No. of channels
 | Signals monitored | Important features |  
							| DIN-rail mounting devices |  
							| MTL5314 | 1 | 4/20mA | Configurable, one or two alarms |  |